At a glance
| Feature | Astra Tech Implant EV | NobelActive, original family |
|---|---|---|
| Implant body | Grade 4 titanium | Grade 4 titanium |
| Surface | OsseoSpeed | TiUnite or TiUltra |
| Body design labels | Straight or conical, with separate Profile model | Expanding tapered body with double threads |
| Restorative identification | EV connection size and abutment indexing | 3.0, NP, RP or WP platform |
| Example catalog reference | 26323, 4.2 S, length 11 mm | 300252, TiUltra RP, 4.3 × 11.5 mm |
| Head-to-head outcome | No direct result verified for this pair | No direct result verified for this pair |
Same material description, different surfaces
OsseoSpeed is the surface named on the Astra Tech Implant EV data sheet. NobelActive can carry TiUnite or TiUltra. A surface describes what the manufacturer does to the outside of the implant body. The final tooth's ceramic, the abutment and the screw need their own entries if you are comparing material choices.
How the catalog describes a connection
Dentsply Sirona records an EV size and offers different indexing arrangements for different abutments. Nobel Biocare's original NobelActive instructions give platform sizes from 3.0 through WP. A label such as RP has meaning within the Nobel system. A diameter on one manufacturer's chart cannot be used as a conversion to the other manufacturer's components.
Reading an evidence claim
A retrospective EV study followed 49 implants in 19 patients and investigated aspects of the earlier Astra Tech TX design in laboratory tests. A separate full-arch trial compared NobelActive with Straumann BLX. Neither provides a patient-outcome comparison between EV and NobelActive. Device-specific papers can describe experience with each implant, but the available evidence here cannot rank the pair.
Comparing two complete plans
Ask each restoring dentist to identify the exact implant, abutment type, temporary restoration and definitive tooth or bridge. Then compare which parts the written fee includes and which practice can service them. Two offers can use the same implant metal while covering very different restorations.
Sources and evidence
- Dentsply Sirona US catalog, Astra Tech Implant EV
- Dentsply Sirona Astra Tech Implant EV data sheet, 32671787-USX-1904
- Nobel Biocare, article 300252, NobelActive TiUltra RP
- Nobel Biocare IFU1001, English edition issued June 19, 2025
- OsseoSpeed EV retrospective study, PubMed abstract, PMID 28834532
- Papi and colleagues, 2025 EuroPerio abstract O012, three-year results